VE3KER installed in Genet Building, Vimy Barracks
2000? |
|
|
Replaced 6AL5 in Rx |
R White |
|
replaced COR panel - receiver taken out - squelch action poor |
VE3MW |
|
reciever replaced operation OK.COR does not release when sig goes off. taking COR in for repairs |
VE3MW |
|
Repeater now in basement of VE3BEO to put in new cabinet, and to be realigned |
VE3CJA |
|
2W output, worked W2EAP, VE3RL, VE3NF, VE3CJA, VE3GTD, from basement, using 5/8 antennas on tower, also working OK as a repeater. C.O.R. OK. RVCR OK, Identifier OK. TX OK on low power only. |
VE3BEO |
|
Rig all complete in new cabinet. All OK, except TX no good on hi-pwr. OK on low with about 5-6 watts out and 3 min Timer cuts off rig. |
VE3BEO |
|
All good except 5 min Timer. Working in basement of
VE3BEO. |
|
|
VE3NF and VE3BEO/3 worked OK to Hartington, 15 miles. During the day the 12V transmit relay controls welded closed and the TX ran until it blew the 3A AC fuse. |
|
|
Replaced 12V Relay and 1-2E26 |
|
|
5 min Timer not working right. |
VE3BEO |
|
Repeater worked OK Amherstview VE3BEO/3 to VE3NF and W2EAP - Dexter. Sounds OK |
VE3MW |
|
VE3BEO/3 12 miles east of Kgtn worked VE3CJA, VE3NF, and at HWY 15/401 worked VE3RL, BLVL, FB sigs both ways. TX on LO as plate voltage (500V) on 2E26 causes excessive plate dissipation ON HI. |
VE3BEO |
|
Following modifications were made by VE3BEO & VE3CLH
to protect the 2E26s from avalanching in
|
VE3BEO |
|
5 min Timer only problem left. |
VE3BEO |
|
5 min Timer Trouble, caused by a surge thru the SCR by the discharge of 250/50 mfd, cleared by putting extra K3 V relay contacts in K6/K7 operate path. Repeater ready to go back to VE3RCS (at last!!) |
VE3BEO |
|
Cancel above - the 5 min Timer locks up K7 due to 50/25 V capacitor, isolating relay contacts, plus an extra relay to open off the capacitor, or s/c, it are only partially effective, it will be OK for a period & then the surge will cause K7 to lock up to the SEC CCT, and disable TX. |
VE3BEO |
|
3A Hi Volt AC fuse blew due to Xd 2E26 in final - replaced &OK. placed 5.6K in gate lead to 5 min SCR - both timers seem to be ok |
VE3BEO |
|
Repeater moved back to VE3RCS by Bill Thompson
VE3KCF & sons, Bob White
VE3AHJ, Leon Brown
VE3MW, Bernie Burdsall
VE3BEO, Jerry Greif
VE3GTD |
|
|
found short in Receiver ant lead - possibly at ant. Pre-amp & cavity repeaked Receiver now sensitive at .15 mu. - Tx repeaked to 15 W VE3AHJ designed & built a 19' ground ant for temporary use. VE3GTD/M now puts in a 5&9 sig |
VE3BEO |
|
VE3BEO, VE3MW, VE3AHJ spent the afternoon taking off all the RG17 Connectors for the upper ant - splices were put on instead. Repeater now using both Tower Ants for the first time. It is suspected that Kingston coverage may still be poor. Rx really have to be peaked up. |
VE3AHJ - |
|
VE3MW, VE3BEO found no modulation caused by open switch on T.X. Repaired & OK. Peaked up receiver but found that pre-amp was intermittant. Taken home for VE3MW to repair. |
|
|
Preamp repaired & installed Cavities returned to .3mv input there is a slight amount of desensitation will let repeater run for a week or so before we do anything. |
|
|
retune cavities - replaced 7C5 tubes in doubler circuit - output noise reduced 2025 DCT/Sept 23/71 |
|
|
removed cavities & replaced 1 pilot lamp |
initialed LB |
|
1900 DST - replaced cavities & all tubes replaced & good with excitation of driver - will replace latter - grounds installed between all panels |
VE3MW |
|
replaced 2 6AK5 RF amp tubes in the receiver - appears to be intermittant in receiver - no desensitation apparent - ants interchanged - VE3AHU/M sigs from Amherstview very good - Identifier not working returning to shop for repair |
VE3BEO |
|
Repaired RG17 Break on upper Ant. switched inputs - Tx now on upper, Rx now on Lower Ant |
VE3AHJ |
NOTE: Looks like the above entry was placed by mistake on wrong page in the Log Book, as the next page in the log continues on with 9 Oct 71 - 22 Jan 72 (Chip, VA3KGB, 21 July 1999) |
||
|
replaced 2 - 6AK5 - set up COR |
VE3MW |
|
reinstalled ID keyer - lowered tone output - modified audio TX input - repair TX co-ax |
VE3MW |
|
Receiver insensitive - checked with Boonton Gerry 60K vVs
for 20 db quieting. Checked preamp - OK; |
|
|
Receiver installed 1245 |
signed Leon |
|
temporary grd plane installed |
VE3BEO |
|
1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 |