DATE | ACTION | BY WHOM |
|
Repeater locking up on TX occasionally. Appears to be heat related. |
|
Repeater locked on solid TX - unable to remotely turn off Transmitter - can not tell if Receiver/Controller accepting codes or not. Installed backup repeater - no voice ID. Transmitter was on for approx 16 hours solid - heat sink barely warm!! | ||
Problem was caused by plastic housing of relay warping - caused TX to remain on. Relay replaced and firmware upgraded. | Tom VE3UDO |
|
Normal Repeater placed back in service. Checks out OK. | Tom VE3UDO Chip VA3KGB |
|
May 99 | Standby Repeater and duplexer cavities mounted in a portable rack system which allows the unit to be portable and only requires connection of power and antennas for full operation. Rack was donated to KARC by ESG Canada. Stored at QTH of Chip, VA3KGB (Backup repeater was displayed at public functions during summer) | Chip VA3KGB |
Dec 99 | Back up repeater and and 2 m antenna installed at Kingston Psychiatric Hospital as part of the City of Kingston Y2K Watch. KPH has full time Emergency Power. | VE3UDO VE3UIN VE3VJF VA3KGB Alex (son of VA3KGB) |
|
1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 |
|